New: hand contact lab and near-ear fork
PARAFIELDRESEARCH SYSTEMS
NATIVE RENDER VIEWERModel & evidence ↗

Latest source sound iteration — named, playable comparisons

PRIMARY TASK / WET-CONTACT SOUND

Compare against the actual target.

The plate sounds below did not meet the requested tongue–saliva/ear target. Review a new, separately labeled pressure-release hypothesis against a local reference and record what is missing.

Open target listening comparison →

Four generated source probes · local-only reference playback · item/action research · no claim of completed wet-ear realism.

ACOUSTICS / EXPERIMENT 01

KU100 Contact Lab

Engineering fixtures retained for diagnostics. These are not the accepted target sound.

LOADED EXPERIMENT

Native audio and simulation state are loaded together.

WAITING FOR RENDER
01

Contact geometry

No native state loaded
Receiver LReceiver RActuator
DRAG TO ORBIT · SCROLL TO ZOOM
02

Signal observatory

ACTUAL RENDER

Binaural waveform

WAV sample amplitude
LeftRightSame scale · click to seek

Contact excitation

N
NormalFrictionSolved contact force

Cavity pressure

Pa
LeftRight—

Mechanical energy

J
StoredInputDissipated
Import a native render to begin0.000 / 0.000 s
Stereo WAV · no normalizationSource state + receiver output
Both ears · playback only
LEFT RMS—dBFS · original WAV
RIGHT RMS—dBFS · original WAV
PEAK AMPLITUDE—Shared stereo scale
CONTACT FORCE—N · current native state
ENERGY BALANCE—J · current residual
03

Define the next experiment

OFFLINE RENDER

Edit the source scene, export it, then run the native solver. Import the resulting bundle here to hear and inspect the new result.

No scene loaded

Edits never change the audio currently loaded. Native validation remains authoritative for physical parameter limits.

NATIVE RE-RENDER
python scripts/render.py --scene scene.json --out outputs/experiment
04

Know what is modeled

EVIDENCE & LIMITS
MEASURED

KU100 airborne transfer shape

The airborne mode uses measured directional transfer shape and relative distance scaling. Absolute airborne pressure is uncalibrated. This bank does not calibrate contact, materials, or internal head transmission.

Near-field KU100 dataset ↗
GENERIC

Contact mechanics & geometry

The fixture and its contact patch are model geometry. Treat predicted local pressure and energy as solver outputs, with calibration and convergence limits described by each export.

CAPTURE CHAIN

Load a render to inspect its declared sensitivity, electronic gain, and ADC scale.

COMPARE

KU100 ≠ 3Dio

KU100 uses a head enclosure; 3Dio uses an ear-and-disc assembly. A KU100 transfer bank cannot establish a 3Dio response. Comparison needs receiver-specific measurements and the same physical excitation.

KU100 ↗ · Free Space ↗ · Pro II ↗
Render provenance & numerical metrics+
No native bundle loaded.
DATA ATTRIBUTION

KU100 near-field receiver derivative: CC BY-SA 3.0. Measurements by J. M. Arend, A. Neidhardt and C. Pörschmann. This project repackages the circular responses and applies the authors' relative-distance corrections; it does not supply device calibration.

Original dataset ↗Author corrections ↗Data license & notices ↗

Imported bundles stay in this browser. No upload, server rendering, or external audio processing.